(4) Install four machine screws (26) and secure electrical contact assembly
(26) to armature lever relay push bars.
E l e c t r i c a l contact kit.
k.
Position magnet spring, magnet frame (29) and magnet strap into magnet
(1)
housing.
Install two machine screws (27) and secure magnet spring and magnet frame
(2)
(30) to magnet housing with magnet strap.
Install by plugging electrical coil (30) into socket on magnet housing of
(3)
e l e c t r i c a l contact kit (24).
Install by attaching armature spring plate (32) to slotted ends of each
(4)
armature lever relay push bars.
Lower armature lever relay (31) into each slot on armature lever relay
(5)
push bars as noted during disassembly.  It may be necessary to depress
armature spring plate (32) slightly to accommodate armature lever relay
(31).
P o s i t i o n cover on electrical contact kit (24).
(6)
Install two machine screws (33) and secure cover.
(7)
l.
M o t o r starter.
(1)
Position motor starter over mounting screw holes on motor controller
panel.
(2) Install three mounting screws and secure motor starter to panel.
m.
Replace motor controller as specified in paragraph 2-222.