(3) Install four machine screws (8), lockwashers (7) and plain hex nuts (6)
and secure rotary switch to motor controller.
(4) Connect electrical leads to rotary switch. (Internal wiring). Remove
tags.
Terminal board.
c.
(1) Install terminal board marker strip (11) at designated location on motor
controller panel.
(2) Position terminal board (9) and end section (10) over mounting screw holes
on motor controller panel.
(3) Install two machine screws (14), lock washers (13) and plain hex nuts (12)
and secure terminal board to motor control panel.
(4) Connect electrical leads to terminal board. (Internal wiring). Remove
tags.
Fuseholder block.
d.
(1) Position fuse blocks (28) and (33) over mounting screw holes on motor
controller panel.
(2) Install two machine screws (32), lockwashers (31) and plain hex nuts (30)
and secure each fuse block to motor controller panel.
(3) Connect electrical leads to fuse blocks. Remove tags.
e.
Position transformer (1) over mounting screw holes on motor controller panel.
(2) Install four machine screws (4), lockwashers (3) and plain hex nuts (2)
and secure transformer to motor controller panel.
( 3 ) Connect electrical leads to transformer. (Internal wiring). Remove tags.
Overload coils.
f.
(1) Position motor starter (22) on a clean flat surface.
(2) Refer to paragraph 2-222, to install thermal release relay.
(3) Overload coils (23).
I n t e r l o c k / s h u n t coil/electrical contact assembly.
g.
(1) Refer to paragraph 2-223, to install auxiliary contact.
(2) Install interlock (26).
( 3 ) Install shunt coil (25).
(4) Install electrical contact assembly (27).