Repair at this level of maintenance is by replacement of pressure gauge (1).
Replace pressure gauge (1).
a.
(1) Place pressure gauge (1) in position and secure using capscrews (2).
(2) Apply teflon tape to fitting on pressure gauge (1).
(3) Install reducer (5) on pressure gauge (1).
(4) Install tee (4) on reducer (5).
(5) Connect tubing (3) to tee (4).
b. Operational check.
(1) Remove warning tags.
(2) Open fresh water pump suction and discharge valves.
(3) Operate system; refer to TM 55-1905-223-10.
(4) Check for leaks in system; retighten connections as necessary.
(5) Check pressure gauge for proper operation.