Custom Search
 
  
 
TM 55-1905-223-24-18-1
Repair Piping Gauge Assembly.
2-344.
This task covers: Repair.
Equipment Condition
Tools
At Auxiliary Machinery Motor Control
Tool kit, general mechanic's,
Center, press Air Compressor No. 1
and No. 2 STOP pushbuttons, set
circuit breakers to OFF position.
Materials/Parts
Tag switches "Out of Service - Do
Not Operate."
Piping system, compressed air
P/N 8551031, refer to
General Safety Instructions
TM 55-1905-223-24P
Pipe gauge assembly,
P/N 05-2400-0001
WARNING
Gauge assembly P/N 05-2400-0003
Pressure gauge (0-450 psi)
Ensure system is turned OFF and
P/N 33-2870-1075
q
tagged to prevent operation during
Pressure gauge (0-250 psi)
maintenance.  Generated pressure
P/N 33-2310-1075
could cause injury.
Teflon tape, Item 5, Appendix C
U t i l i t y p a i l , Item 13, Appendix C
Use extreme care when breaking
q
system connections.  Escaping
pressure and/or fluids could cause
injury.
Clean up spills immediately.
q
Spills create an unsafe working
area.
PEPAIR
Refer to paragraph 2-335 for procedures.
2-1011


 


Privacy Statement - Copyright Information. - Contact Us