Table 3-2. Troubleshooting - CONT
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WASHER MACHINE - CONT
STEP 5. Check temperature switch.
Replace switch if defective (para. 3-92).
STEP 6. Check pressure switch.
Replace switch if defective (para. 3-92).
35. Excessive vibration.
STEP 1. Check centering springs.
Connect or replace springs (para. 3-95).
36. Unit starts cycle then stops.
STEP 1. Check top limit switch with multimeter.
Replace defective switch (para. 3-90).
37. Water fill won't stop.
STEP 1. Check pressure switch.
Replace switch if defective (para. 3-92).
STEP 2. Check timer.
Replace timer if defective (para. 3-92).
STEP 3. Check for leaks in pressure hose.
Replace pressure hose (para. 3-95).
38. Slow or no spin.
STEP 1. Check for loose or broken drive belt.
Replace belts (para. 3-107).
STEP 2. Check brake pads.
Replace brake pads (para. 3-97).
STEP 3. Check for binding water pump.
Replace water pump (para. 3-100).
STEP 4. Check drive motor
Replace motor if defective (para. 3-102).
STEP 5. Check timer
Replace timer if defective (para. 3-92).