Custom Search
 
  
 
TM 55-1905-223-24-18-2
3-42. Replace/Repair Level Sight Indicator. (Figure 3-39)
This task covers:
a. Removal
b. Disassembly,
c. Repair
d. Assembly
e. Replacement
INITIAL SETUP:
Tools
Equipment Condition
Tool kit, general mechanic's,
Inlet/outlet valves to /from tank
closed and tagged "Out of Service Do Not Operate."
Level of fluid in tank must be lower than indicator pick-
up.
Materials/Parts
Indicator, VLI-86501-36
Gasket P/N 86104
Float P/N 86523
Float tag P/N 86474
Warning tags, Item 1, Appendix C
REMOVAL
a. Remove flange mounting hardware and lift level sight indicator out of tank.
b. Remove flange gasket from tank flange.
DISASSEMBLY
a. Position level sight indicator on a clean flat surface.
b. Loosen and remove two retaining straps (2, Sheet 1) securing flag assembly (3) to magnetic chamber
assembly (1). Remove flag assembly.
c. Remove four hex head cap screws (9, Sheet 2) flat washers (10) and lockwashers (11) securing
magnetic chamber assembly (1) to mounting flange and float chamber assembly (4).
d. Separate magnetic chamber assembly (1) from mounting flange and float chamber assembly (4).
e. Remove gasket (13).
f. Remove cotter pins (7).
g. Separate and remove magnet assembly (6) from float rod (8).
h. Remove cotter pin (12).