f. Fuseholder.
(1) Position fuseholder (16) and fuse cartridge (15) on front panel.
(2) Install terminal lug (8) at rear of fuseholder.
(3) Connect electrical wire ends to fuseholder. Remove tag.
g. Sonalert alarm.
(1) Position sonalert alarm (14) at rear of front panel.
(2) Install preformed packing (13) and terminal lug (8) on sonalert alarm at front panel.
(3) Connect electrical wire ends to sonalert alarm. Remove tag.
h. Toggle switch.
(1) Position toggle switch (10) at rear of front panel.
(2) Install preformed packing (9) and terminal lug (8) on toggle switch at front panel.
(3) Connect electrical wire ends to toggle switch. Remove tag.
(4) Repeat steps (1) through (3) to install toggle switch (12).
i. Indicator light.
(1) Attach identification plates (7) and identification plate (11) to front panel.
(2) Position indicator light (5) on front panel.
(3) Install terminal lug (8) at rear of indicator light.
(4) Connect electrical leads; and install insulating tubing (6) at rear of indicating light. Remove
tag.
(5) Repeat steps (2) through (4) to install remaining indicator lights.
j. Meter.
(1) Position meter (4) on front panel.
(2) Install four machine screws (1), lockwashers (2), and plain hex nuts (3) and secure meter to
front panel.
(3) Connect electrical leads to meter. Remove tags.
(4) Repeat steps (1) through (3) to install remaining meters.