WARNING
ELECTRIC SHOCK HAZARD. Ensure the electrolytic (starter)
capacitor leads are shorted together to discharge the capacitor
before disassembly.
d. Remove electrolytic fixed capacitor (8) electrical lead quick disconnect and remove capacitor.
e. Disconnect and tag electromagnetic relay (7) electrical leads and retaining screw, and remove relay.
f. Disconnect and tag circuit breaker (6) electrical leads and retaining screw and remove circuit breaker.
g. Sweat off refrigerant lines to each side of filter dryer (2) and remove filter dryer.
h. To remove liquid sight indicator (3), sweat refrigerant lines off each side of unit and remove.
i. Disconnect and tag low level control (5) electrical leads and retaining screw and remove low level
control.
REPAIR
Repair at this level of maintenance is by replacement of worn or defective parts.
ASSEMBLY
a. Install low level control (5) in control panel with retaining screw, remove tags, and connect electrical
leads.
b. Sweat on liquid sight indicator (3) refrigerant connections.
c. Sweat on filter dryer (2) refrigerant connections.
d. Install circuit breaker (6) with retaining screw, remove tags, and connect electrical leads.
e. Install electromagnetic relay (7) with retaining screw, remove tags, and connect electrical leads.
f. Install electrolytic fixed capacitor (8) in mount and connect electrical lead quick disconnect.
g. Snap on axial fan impeller (1) on condenser fan motor (9) shaft.
h. To install condenser fan motor (9), perform the following:
(1) Install condenser fan motor and impeller fan (1) in condenser unit.
(2) Install condenser fan motor mounting bolts.
3-303


 