Custom Search
 
  
 
TM 55-1905-223-24-18-2
3-125. Replace/Repair Annunciator (Engineer's Quarters and Galley). (Figure 3-112)
This task covers:
a. Inspection
b. Removal
c. Repair
d. Replacement
INITIAL SETUP
Tools
Equipment Condition
Tool kit, electrician's,
Electrical power to machinery plant
monitoring and alarm system secured
and tagged "Out of Service - Do Not
Operate." TM 55-1905-22-223-10
Materials/Parts
Warning tags, Item 1, Appendix C
INSPECTION
Check exterior of annunciator for loose or missing mounting hardware. Make sure audible alarm is
screwed in securely and lamp on (Engineer Assistance Needed) push button is illuminated. Open
door and check for loose connections on internal wiring, secure as required.
REMOVAL
a. Loosen two latch screws (4) to release latches (5).
b. Swing door (2) to the left to gain access to interior.
c.
Tag and disconnect electrical power cables (6) from terminal board TB1.
d. Remove four machine screws (3).
e. Remove annunciator (1) from bulkhead.
REPAIR
Repair at this level of maintenance is by replacement of annunciators (1).
REPLACEMENT
a. Position annunciator (1) on bulkhead and secure with four machine screws (3).
b. Connect electrical power cables (6) at terminal board TB1 and remove tags.


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business