Quantcast Repair Bilge/Ballast Pump Power Distribution

Custom Search
TM 55-1905-223-24-18-2
3-160. Repair Bilge/Ballast Pump Power Distribution. (Figure 3-146)
This task covers:
a. Repair.
Equipment Condition
Tool kit, electrician's,
Electrical power secured at ship
service switchboard 240V distribution
and tagged "Out of Service - Do Not
Operate." TM 55-1905-223-10.
Warning tag, Item 1, Appendix C
Death, serious injury, or equipment damage can result from
contact with live electrical circuits. Before beginning work on
this, or any other electrical equipment, turn power and control
voltage circuit breakers OFF and tag "Out of Service - Do Not
Repair at this level of maintenance is by replacement of electrical cables.
a. Disconnect electrical power cables (1 and 2) from ship service switchboard and termination.
b. Run new cable. Attach to ship service switchboard and termination.
Change 1 3-539