Custom Search
 
  
 
TM 55-1905-223-24-18-2
SECTION II MAINTENANCE ALLOCATION CHART FOR ELECTRICAL SYSTEM
(1)
(2)
(3)
(4)
(5)
(6)
MAINTENANCE LEVEL
GROUP
COMPONENT/
MAINTEN ANCE
UNIT
INTERMED. DEPOT
TOOLS AND
NUMBER
ASSEMBLY
FUNCTION
C
O
F
H
D
EQUIPMENT
REMARKS
1812010305 SWITCH, DISCONNECT
REPLACE
1.0
1
REPAIR
1.0
1
18120104
PANEL,POWER
INSPECT
0.2
DISTRIBUTION (P203)
REPLACE
1.5
1
REPAIR
1.0
1.5
1.5
1
1812010401 DOOR ASSEMBLY
REPLACE
0.5
1
REPAIR
1.0
0.5
1
1812010402 BREAKER,PLUG IN UNIT
REPLACE
0.5
1
REPAIR
0.5
1
1812010403 LUG,MAIN INTERIOR
REPLACE
0.5
1
REPAIR
0.5
1
18120105
PANEL,POWER
INSPECT
0.2
DISTRIBUTION (P204)
REPLACE
1.5
1
REPAIR
1.0
1.5
1.5
1
1812010501 DOOR ASSEMBLY
REPLACE
0.5
1
REPAIR
0.5
1
1812010502 BREAKER,PLUG IN UNIT
REPLACE
0.5
1
REPAIR
0.5
1
1812010503 LUG,MAIN INTERIOR
REPLACE
0.5
1
REPAIR
0.5
1
18120106
AUXILLIARY MACHINERY
INSPECT
0.2
MOTOR CONROL CENTER
REPLACE
2.0
1
POWER DISTRIBUTION
REPAIR
1.0
1.5
2.0
1
18120107
FOWARD DECK
INSPECT
0.2
MACHINERY
MOTOR CONTROL CENTER REPLACE
1.0
1
POWER DISTRIBUTION
REPAIR
1.0
1.5
1.0
1
18120108
FIRE PUMP NUMBER TWO
INSPECT
0.2
POWER DISTRIBUTION
REPLACE
1.0
1
REPAIR
1.0
1.0
1
Change 1 B-52


 


Privacy Statement - Copyright Information. - Contact Us