Custom Search
 
  
 
TM 55-1905-223-24-3
Table 2-1. Preventive Maintenance Checks and Services
D-Daily
M-Monthly
Q-Quarterly
A-Annually
B-Biennially
E-Every 1600 Operating Hours
Item
Interval
Items To Be
No.
DM
Q
A
B
E
Inspected/Serviced
Procedures
25
b.
Heat the water to activate the temperature
CONT
control. The horn or warning device should
sound at, or near, 200 (93 ).
F
C
c.
Replace sensing unit if necessary.
Check the lubricating oil pressure sending device..
a.
Check for oil leakage from the sender. Replace
if required.
b.
Check for broken or disconnected wire. Repair
as required.
c.
With the wire disconnected from the sender,
check resistance from the terminal post to
equipment ground (metal chassis). If the read-
ing is not between 227 to 257 ohms, replace.
26
Injectors
Replace injectors (paragraph 2-40).
27
Fuel Pump
Replace the fuel pump (paragraph 2-37).
28
Water Pump
Replace the water pump (paragraph 2-33).
29
Turbocharger Bearing
Check the bearing radial and axial clearances.
a.
Remove the shield and piping from the turbo-
b.
Measure the axial (end-to-end) clearance of the
shaft with a dial indicator. Clearance should be
no greater than 0.018 inch (0.46 mm).
2-18


 