Custom Search
 
  
 
TM 55-1905-223-24-3
REPLACEMENT
NOTE
Apply teflon pipe thread lubricant to threaded fittings.
a. If the elbow (15) and reducer (16) were removed, apply a thin coating of teflon pipe thread lubricant to
the threads, and replace them on the engine.
b. Mount the pump (6) to bracket (1) with the capscrews (2) and washers (3, 4). Apply a thin coating of
teflon pipe thread lubricant to the threads and install the pipe bushing (7) pipe nipples (8, 10) and elbow
(9) to the bottom of the pump (6).
c.
Install the shutoff valve (11) and elbow (13) and connect the ho e (14) to elbows (13 and 15) and
s
tighten.
d. Connect the clamp (12) to hose (14). Tighten hardware.
e. Connect the outlet pipe to the top of the pump at point (5).
f.
Operate the sump pump (TM 55-1905-223-10) and check for leaks. Tighten fitting as required.
g. Return the generator to service. TM 55-1905-223-10.