TM 55-1905-223-24-3
FIGURE 3-8. Generator Coupling and Housing.
REPLACEMENT
CAUTION
Do not use the generator cooling fan for lifting or rotating the
rotor assembly. Do not force the alignment of the generator.
Move the generator assembly slowly from side to side or up and
down as necessary.
a. Loosen the capscrews which mount the generator supporting crossmember(s) to the subbase side rails.
b. Install two guide studs into the flywheel and two in the flywheel housing.