Custom Search
 
  
 
TM 55-1905-223-24-5
Table 2-1. Preventive Maintenance Checks and Services (PMCS)
D-Daily
M-Monthly
Q-Quarterly
A-Annually
B-Biennially
Item
Interval
Items To Be
No.
DMQAB
Inspected/Serviced
Procedures
21
Safety controls continued
c. Disconnect the sending device from the main oil rifle
on the fuel pump side of the engine and use a sending
device of known accuracy to verify the reading of the
suspect unit.
22
Injectors
Replace injectors (paragraph 2-35).
23
Water Pump
Replace the water pump (paragraph 2-29).
24
Turbocharger Bearing
Check the bearing radial and axial clearances.
Remove the shield and piping from the turbocharger.
Measure the axial (erg-to-end) clearance of the shaft with a dial indicator. Clearance
should be not greater than 0.018 inch (0.46 mm).
Use a wire feeler gauge and measure the radial (side-to-side) clearance. Hold the shaft
toward the feeler gauge to check. The clearance should be no greater than 0.033 inch
(0.84 mm).
Replace the turbocharger if either measurement exceeds specifications above, Refer to
NOTE
This procedure is to be performed
after every 50 hours of operation.
Change 2
2-19


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business