Custom Search
 
  
 
TM 55-1905-242-14
0014 00
CONTROL AND DISTRIBUTION PANEL (continued)
83.
WHITE LTS PILOTHOUSE CHART
Overload protection for the pilothouse white lights, chart light, and com-
& COMPASS Circuit Breaker
pass light. ON/OFF for the pilothouse lights is controlled by a switch on
the pilothouse console. ON/OFF for the chart light and compass light is
controlled by switches on the units.
84.
VENT FAN W/C Circuit Breaker
Overload protection for the water closet compartment ventilation fan. ON/
OFF is controlled by a door switch and timer.
85.
ENGINEALARM PANEL Circuit
Overload protection for the engine alarm system. ON/OFF is controlled
Breaker
by this breaker and by fuel pressure switches on the engine.
86.
VENT FAN BATTERY COMP Circuit
Overload protection for the battery compartment ventilation fan. ON/
Breaker
OFF is controlled by this circuit breaker.
87.
HYD CRANE DIVERT VALVE Circuit
Overload protection for the crane diverter valve. ON/OFF is controlled
Breaker
by a switch located on the pilothouse console.
88.
FIRE PUMP CLUTCH Circuit Breaker
Overload protection for the fire pump clutch. ON/OFF is controlled by a
switch on the pilothouse console.
89.
WEATHER DECK LIGHTS Circuit
Overload protection for the white deck lights. ON/OFF is controlled by a
Breaker
switch on the pilothouse console.
90.
RED CARGO LIGHTS Circuit Breaker
Overload protection for the red cargo lights. ON/OFF is controlled by a
switch on the pilothouse console.
91.
GEN ALARM Circuit Breaker
Overload protection for the general alarm system. ON/OFF is controlled
by a rotary switch on the pilothouse overhead.
92.
FIRE DETECT SYSTEM Circuit
Overload protection for the fire detection system. ON/OFF is controlled
Breaker
by a switch on the alarm panel.
93.
RUDDERANGLE & TANK GAUGES
Overload protection for the rudder angle indicator and the tank level
Circuit Breaker
guages. ON/OFF is controlled by this breaker.
94.
VENT FAN NO. 1 ACCOM Circuit
Overload protection for accommodation module ventilation fan number
Breaker
1. ON/OFF is controlled by this breaker.
95.
VENT FAN NO. 2 ACCOM Circuit
Overload protection for accommodation module ventilation fan number
Breaker
2. ON/OFF is controlled by this breaker.
96.
SPARE Circuit Breaker
Spare circuit breaker provided for expansion.
97.
SPARE Circuit Breaker
Spare circuit breaker provided for expansion.
98.
SPARE Circuit Breaker
Spare circuit breaker provided for expansion.