Custom Search
 
  
 
TM 55-1905-242-14
0019 00
HYDRAULIC ACCUMULATORS
32.
Accumulator Gauges
Each accumulator, two port and two starboard, has a gauge to indicate the
pressure present in the accumulator.
33.
Accumulator Gauge Shutoff Valves
Valves allow the accumulator gauges to be isolated from the accumulators
for service. During normal operation, the valves are OPEN, allowing the
gauges to indicate the pressure present in the accumulators. When the
valves are CLOSED, the accumulator gauges are isolated from the system.
34.
Accumulator Shutoff Valves
Valves allow the accumulators to be isolated from the starting system.
During normal operation, the valves are OPEN, making the accumulator
pressure available to the starting system. When the valves are CLOSED,
the accumulators are isolated from the system.
32
33
34
0019 00-9


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business