TM 55-1905-242-14
0025 00
OILY WATER COLLECTION SYSTEM
WOT DISCH
PRESSURE DISCH
7
6
WOT SHORE CONN
VENT
LUBE OIL
WASTE
CHANGE SYS
OIL
(LOCS) HOSE
SIGHT
TANK
CONN TO
GLASS
ENGINES
2
3
4
TO BILGE
1
BILGE
MANIFOLD
5
3 GPM
WASTE
OILY
Y-STRAINER
PUMP
SYSTEM DIAGRAM
OILY WATER COLLECTION SYSTEM
VALVE ALIGNMENT
OPERATI NG
1
2
3
4
5
6
7
MODE
DRAIN BILGE
OPEN SHUT SHUT OPEN SHUT SHUT SHUT
TO TANK
DRAIN BILGE
OPEN SHUT SHUT SHUT OPEN OPEN SHUT
TO DK CONN
DRAIN ENG &
SHUT OPEN SHUT OPEN SHUT SHUT SHUT
GEAR TO TANK
DRAIN ENG &
SHUT OPEN SHUT SHUT OPEN OPEN SHUT
GEAR TO DK CONN
EMPTY WASTE
SHUT SHUT OPEN SHUT OPEN OPEN SHUT
OIL TANK
PUMP OUT TANK
SHUT SHUT SHUT SHUT SHUT SHUT OPEN
FROM SHORE CONN
(MAXIMUM SYSTEM PRESSURE IS 60 PSI)
END OF WORK PACKAGE
0025 00-3/4 blank