MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Batteries will not hold
1.
Check batteries and cables (WP 0059 00).
Correct as necessary
a charge.
2.
Test alternators (WP 0060 00).
If alternator(s) are defective,
notify unit maintenance for
replacement.
3.
Check that battery charger is ON.
If battery charger is ON, but
not charging batteries, notify
unit maintenance.
4.
Steps 1-3 above check OK, but
Notify unit maintenance to
batteries will not hold a charge.
test batteries.
5. ENGINE START button
1.
Attempt to crank the engine with the manual
1.
If the engine does not crank
does not crank engine.
start button located on the control valve.
with the manual start button,
the problem is hydraulic, not
electric. Refer to WP 0038 00
for hydraulic starting
system troubleshooting.
2.
If the engine cranks with the
manual start button, the
problem is electrical.
Continue with this
troubleshooting
procedure.
2.
Check the switches and wiring for obvious
If the switches and/or wiring
damage.
are damaged, notify unit
maintenance for repair.
6. Lights do not light up.
1.
Check that the circuit breaker for the affected
Set to ON the circuit breaker.
circuit is ON.
2.
Check to see if bulb is defective.
Replace bulb (WP 0063 00).
3.
Check for obvious damage to switches and
If damage exists, notify unit
wiring.
maintenance for repair.
END OF WORK PACKAGE