Custom Search
 
  
 
TM 55-1905-242-14
0063 00
REPLACE--SWITCH (continued)
2.
Pull the switch plate (21) away from the switch box (22). The switch (23) will remain attached to the switch plate.
3.
Set the multimeter to the Vdc (Volts direct current) setting and check for available voltage at the switch's wiring
connections. If no voltage is noted, proceed to the next step If voltage is noted, ensure that the proper circuit breaker
has been properly secured.
4.
Label and disconnect the wiring from the switch (23).
5.
Remove the nut (24) that attaches the switch (23) to the switch plate (21), and remove the switch from the switch
plate.
6.
Install a new switch (23) on the switch plate (21) and secure it with the nut (24).
7.
Connect the wiring to the switch's (23) terminals using the labels from step 4 as a guide.
8.
Install the switch plate (21) onto the switch box (22), and secure it with the screws (20).
9.
Remove the lockouts and tagouts and check the operation of the system.
END OF WORK PACKAGE
0063 00-6


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business