Custom Search
 
  
 
TM 55-1905-242-14
0083 00
REMOVAL (continued)
2.
Disconnect the throttle cable and articulator from the local control unit in the engine room by using the following
procedure:
a.
Remove the nut (9) and washer (10) that secure the cable connector (11). Remove the cable connector from its hole
in the local control head.
b.
Loosen the locknut (12) and remove the cable connector (11) from the articulator (13).
c.
Remove the clamping screw (18) from the local control unit (19).
NOTE
Cotter pins, lockwashers, locking nuts, and similar locking devices shall be discarded after removal and replaced with
new cotter pins, lockwashers, locking nuts and similar locking devices.
d.
Loosen the locknuts (14 and 15), and remove the cable adapter bushing (16) from the articulator (13) and throttle
cable (17).
e.
Follow the routing of the throttle cable (17) and disconnect it from any vessel structure that supports it. Pull the
cable down.
3.
Disconnect the governor control rod assembly from the local control unit by using the following procedure:
a.
Measure and record the length from center to center of the rod ends (20) before removing the governor control rod.
b.
Remove the nuts (21) and lockwashers (22) that secure the rod ends (20).
c.
Remove the rod ends (20) from the local control unit (19) and the governor control rod.
17
15
16
18
14
20
19
13
24
25
23
24
12
25
22
11
21
10
9
20
21
22
0083 00-2


 


Privacy Statement - Copyright Information. - Contact Us