Custom Search
 
  
 
TM 55-1905-242-14
UNIT MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
STARTING HYDRAULIC SYSTEM RECHARGING PUMP, REPLACE
INITIAL SETUP:
Tools and Special Tools:
Materials/Parts:
Tool Kit, Mechanic's Rail and Marine (Item 1,
Hydraulic Fluid (Item 1, Table 2, WP 0230 00)
Table 1, WP 0230 00)
Cleaning Solvent MIL-PRF-680 (Item 2, Table 2,
Suitable Drain Pan
Gloves, Chemical Protective (Item 3, Table 2, WP 0230 00)
Equipment Condition:
Goggles, Industrial, No Vents (Item 4, Table 2,
Propulsion engines secured, locked out, and
tagged out IAW FM 55-502
Rag, Wiping (Item 5, Table 2, WP 0230 00)
All accumulators blown down
Gasket Flange (p/n GA202082, qty 1)
Personnel Required:
References:
Two Watercraft Engineers, 88L
FM 55-502
TM 55-1905-242-24P (WP 0014)
REMOVAL
WARNING
Cleaning solvent is flammable and its vapor is potentially explosive. Do not use clean-
ing solvent in the vicinity of spark, open flame, or excessive heat. Do not use cleaning
solvent in unventilated spaces. Failure to comply can result in serious injury or death.
Do not allow hydraulic fluid or cleaning solvent to come in contact with unprotected
skin or eyes. Prolonged skin contact can cause illness or injury. Eye contact can cause
serious injury. Always wear chemical protective gloves and goggles when handling
used hydraulic fluid and cleaning solvent. Failure to comply can result in illness, seri-
ous injury, or death.
Hydraulic hoses and lines may be under pressure. Relieve pressure by operating the
appropriate control valve if possible. Loosen fittings on hose lines slowly. Allow oil to
run around threads of fitting, releasing pressure before disconnecting fitting. Releasing
pressurized oil suddenly may cause serious injury or death.
1.
Ensure that all hydraulic pressure is released from the hydraulic system before beginning work.
2.
Don chemical protective gloves and goggles and use a wiping rag and cleaning solvent to clean all contamination from
the work area. This will prevent contamination of the hydraulic system.
3.
Position a suitable drain pan beneath the pump (6) and disconnect the outlet hose (1), inlet hose (2), and return hose (3)
at the elbows (8).
4.
Cap the hoses (1, 2, and 3) to prevent system contamination.
0086 00-1


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business