Custom Search
 
  
 
TM 55-1905-242-14
UNIT MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
AIR CONDITIONING AND VENTILATION SYSTEMS PIPING, VALVES, STRAINERS,
WATER HEATER, REPLACE
INITIAL SETUP:
Personnel Required:
Tools and Special Tools:
Two Watercraft Engineers, 88L
Tool Kit, Mechanic's Rail and Marine (Item 1,
Table 1, WP 0230 00)
Materials/Parts:
Multimeter (Item 2, Table 1, WP 0230 00)
Gloves, Chemical Protective (Item 3, Table 2, WP 0230 00)
Drop Light, Extension (Item 16, Table 1,
Goggles, Industrial, No Vents (Item 4, Table 2,
Suitable Drain Pan
Antifreeze, Ethylene Glycol Inhibited (Item 6, Table 2,
Equipment Condition:
FRESH WTR TANK PRESS SET and HOT WA-
References:
TER HEATER circuit breakers set to OFF,
FM 55-502
locked out, and tagged out IAW FM 55-502
TM 55-1905-242-24P (WP 0052)
Water heater shutoff valves on starboard pro-
pulsion engine CLOSED, locked out, and
tagged out IAW FM 55-502
REMOVAL
1.
Remove the four bolts (1), four nuts (2), and eight flat washers (3) that secure the accommodation access ladder (4). Lift
the accommodation access ladder clear of the work area.
2.
Remove the two screws (5) that secure the junction box cover (6) to the junction box.
3
3 1
2 3
3
1
2
4
2
2
1
1
3
3
3
3
0131 00-1


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business