Custom Search
 
  
 
TM 55-1905-242-14
UNIT MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
BLACK WATER TANK MONITOR SYSTEM, REPLACE
INITIAL SETUP:
Tools and Special Tools:
Personnel Required:
Tool Kit, Mechanic's Rail and Marine
One Watercraft Engineer, 88L
(Item 1, Table 1, WP 0230 00)
(Trained in Confined Space Entry)
Multimeter (Item 2, Table 1, WP 0230 00)
One Entry Supervisor/Attendant
Equipment Condition:
Materials/Parts:
Void 6 prepared for confined space entry with
Gloves, Chemical Protective (Item 3, Table 2, WP 0230 00)
Confined Space Entry Permit secured, IAW
Apron, Chemical Protection (Item 11, Table 2, WP 0230 00)
Organizational Confined Space Entry SOP
and FM 55-502
References:
RUDDER ANGLE & TANK GAUGES circuit
FM 55-502
breaker set to OFF, locked out, and tagged
Organizational Confined Space Entry SOP
out IAW FM 55-502
TM 55-1905-242-24P (WP 0057)
Potable water tank drained
REMOVAL--TANK UNIT
WARNING
Only properly trained personnel may enter confined spaces, or act as entry supervisors
and/or attendants for those working in confined spaces. Before entering into a confined
space, the space must be cleared for entry and a Confined Space Entry Permit must be
secured. All entry into confined spaces must be in accordance with the Organizational
Confined Space Entry Standard Operating Procedure and FM 55-502. Entry into an
uninspected confined space may result in serious injury or death.
Sewage is a common mode of transmission for parasitic organisms that may have the
capability of causing communicable diseases. Protective gloves and a protective apron
should be worn to help prevent contact with sewage. After coming in contact with
sewage or contaminated equipment, be sure to clean yourself with a disinfectant soap.
Avoid sewage contact with skin abrasions, punctures, cuts, and other open wounds.
Wipe up and clean any spills and/or contaminated equipment using a disinfectant soap.
Failure to comply could result in illness, serious injury, or death.
Replace or repair components only after the affected circuit has been secured, locked
out, and tagged out. Performing replacement with the circuit energized may result in
damaged equipment and serious injury or death to personnel.
1.
Remove the void cover from Void 6 and prepare it for confined space entry in accordance with the Organizational
Confined Space Entry SOP and FM 55-502.
0136 00-1


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business