Custom Search
 
  
 
TM 55-1905-242-14
0151 00
1
4
3
2
CLEANING
1.
If not already on, don chemical protective gloves and goggles.
2.
Clean the threads on the piping (4) and the union (3) with a wire brush.
3.
Clean oily parts with cleaning solvent and wipe dry with clean wiping rags.
INSTALLATION
1.
Wrap only the male pipe threads on the piping (4) and on the union (3) with antiseizing sealant tape. Do not apply
antiseizing sealant tape to the mating surfaces or mating threads on the union.
2.
Thread the union (3) into the check valve (1) and tighten it securely.
3.
Thread the check valve (1) onto the piping (4) and tighten it securely, ensuring that the union (3) is oriented for
connection.
4.
Connect the check valve (1) to the reservoir (2) by connecting the union (3).
5.
Remove the lockouts and tagouts and check the operation of the system, ensuring that the steering system operates
normally and that no leakage is noted.
6.
Replenish the steering reservoir as necessary.
7.
Dispose of used hydraulic oil, cleaning solvent, and contaminated materials in accordance with local regulations.
END OF WORK PACKAGE