Custom Search
 
  
 
TM 55-1905-242-14
0157 00
REMOVAL (continued)
WARNING
Prior to removing any hoses, ensure that the crane boom is sufficiently secured to
prevent any movement of the boom sections. Moving or dropping boom sections
present a fall and/or pinch hazard and can cause serious injury or death.
1.
Don chemical protective gloves and goggles.
2.
Position a suitable drain pan beneath the work area.
3.
Cautiously loosen the swivel fitting (1) on the hose (2) in order to release any residual hydraulic pressure on the system.
4.
Remove one end of the hose (2) from the fitting (3) by unscrewing the swivel fitting (1).
5.
Unscrew the other end of the hose (2) from its fitting (4).
6.
Remove the fittings (3, 4, 5) or valve (6) as required for replacement.
CLEANING
1.
If not already on, don chemical protective gloves and goggles.
2.
Use cleaning solvent to clean all parts that will be reused. Dry the parts with clean wiping rags.
0157 00-2


 