Custom Search
 
  
 
TM 55-1905-242-14
0183 00
INSTALLATION
1.
Wrap the male pipe threads of the counterbalance valve piping (4) with antiseizing sealant tape and install the piping in
the counterbalance valve (3) using the labels from step 5 of Removal as a guide.
2.
Position the counterbalance valve (3) and connect the unions (2) and the hydraulic hoses (1) using the labels from step
4 of Removal as a guide.
3.
Remove the lockouts and tagouts, adjust the counterbalance valve (WP 0150 00), and check the operation of the system.
Ensure that the helm operates normally and that no leaks are present.
4.
Dispose of the used hydraulic fluid and contaminated materials in accordance with local regulations.
END OF WORK PACKAGE
0183 00-2


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business