Custom Search
 
  
 
Section VII. WATER SUPPLY SYSTEM
located just forward of the heating boiler on port side of the
5-76. General
engineroom.
a. General The water supply system of the vessel is a
c. Fresh Water System. The pressure tank and pump
combination fresh and salt water system that utilizes salt
of the fresh water system is identical to that of the sanitary
water for the sanitary disposal from water closets, and fresh
system, but is located aft of the heating boiler on port side of
water for lavatory, shower, water dispenser (cooler), and
the engineroom.
galley. A fresh (potable) water storage tank of 2,756 gallons
is located in the lazarette.
5-77. Water System
b. Sanitary System.  A pressure tank of 42 gallon
a. General Water closets are located in the officer and
capacity draws salt water from the sea chest on port side of
crew (fig. 5-115) wash rooms, with lavatories (wash basins)
the engineroom amidships, with a piston type reciprocating
and shower placement as shown (typical).  Lavatories are
pump controlled by a pressure switch to maintain 40 psi
also placed in the captain and chief engineers staterooms.
pressure on the system. The pressure tank and pump are
5-162


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business