28. Machinery plant alarm rotating beacon (figure 1, item 28). A blue light illuminates and the beacon rotates when the
machinery plant alarm is activated.
29. General alarm rotating beacon (above) (figure 1, item 29). A red light illuminates and the beacon rotates when the
general alarm is activated.
30. Main engine 2 (figure 1, item 30). Main engine 2 is an air-started, fresh water-cooled, main propulsion engine. Main
engine 2 rotates counterclockwise when viewed from the flywheel.
31. Aft sea chest strainer differential pressure gauge (figure 1, item 31). This gauge indicates the differential pressure
across the aft sea chest strainer.
32. Reduction gear 2 (figure 1, item 32). Reduction gear 2 transfers power from the main engine and provides directional
control to the port propeller shaft.
33. Shaft brake panel 2 (figure 1, item 33). This panel provides control for the port shaft brake.
34. FM-200 alarm horn/strobe (figure 1, item 34). The FM-200 alarm horn/strobe provides a visible and audible warning
60 seconds before the FM-200 fire suppression agent is released.
35. Fuel vent flow indicator (figure 1, item 35). The fuel vent flow indicator is provided to check for fuel oil tank accidental
overfill.
36. Fuel oil day tank high level alarm (figure 1, item 36). The fuel oil day tank high level alarm provides a visible and
audible alarm when the transfer of fuel oil to the PORT or STARBOARD fuel oil day tanks have exceeded fill levels.