Custom Search
 
  
 
TM 55-1925-273-10-1
0011 00
11. Load center distribution panel (figure 3, item 11). The load center distribution panel supplies 120V to four distribution
panels and to the machine shop.
12. Horn and PA speaker with volume control (figure 3, item 12). The horn sounds to alert the crew when the sound
powered telephone (in EOS) has an incoming call. The PA speaker with the volume control amplifies messages throughout
the engine room.
13. 440V power panel No. 1 (figure 3, item 13). 440V power panel No. 1 provides 440 volt power distribution for engine
room equipment.
14. Fire alarm pull station (figure 3, item 14). The fire alarm pull station activates the fire alarm when pulled.
15. Sewage discharge pump 1 motor controller (figure 3, item 15). The sewage discharge pump 1 motor controller turns
sewage discharge pump 1 ON and OFF.
16. AMS 1 watertight door hand pump (figure 3, item 16). The AMS 1 watertight door hand pump is used to open and close
the AMS 1 sliding watertight door.
17. Sewage discharge pump 1 (figure 3, item 17). Sewage discharge pump 1 is an electrically powered pump that pumps
contents of the sewage tank to the sewage shore connection or overboard.
18. Aqueous Film Forming Foam (AFFF) pump suction gauge (figure 3, item 18). This AFFF pump suction gauge indicates
the suction pressure of the AFFF pump.
19. Ship's Service Diesel Generator (SSDG) 1 (figure 3, item 19). The SSDG 1 is a battery-started (24 Vdc), fresh water-
cooled, diesel engine-driven service generator providing electric power to the main switchboard.
20. Oily waste storage tank level indicator (figure 3, item 20). The oily waste storage tank level indicator displays the
amount of oily waste present in the tank.
21. 120V emergency distribution panel No. 1 (figure 3, item 21). The 120 volt emergency distribution panel no. 1 provides
emergency power distribution for selected equipment.
22. Battery chargers (figure 3, item 22). Two battery chargers maintain the charge of two battery banks. One charger is for
SSDG 1, the other for the machinery plant monitoring system.
23. Oil Content Monitor (OCM) (figure 3, item 23). The OCM monitors the oil content of the effluent discharge from the
oil water separator and prevents overboard discharge of contaminated effluent.
24. Battery banks (figure 3, item 24). The upper battery bank provides battery power to start SSDG 1 and the lower battery
bank provides power for the machinery plant monitoring system and engine control.
25. Oil water separator (figure 3, item 25). The oil water separator separates oil from water and discharges the water
overboard sending only the separated oil back to the oily waste tank.
26. Oily bilge and oil water separator pressure gauges (figure 3, item 26). The oily bilge and oil water separator pressure
gauges indicate the amount of pressure within the oily bilge and oil water separators.
27. Oily bilge pump (figure 3, item 27). The oily bilge pump is an air powered pump for removing oily water from bilges
and transferring contents of the oily waste drain tank and the oily waste storage tank to the shore connection.
28. Oily bilge strainer (figure 3, item 28). The oily bilge strainer protects the oily bilge pump by removing sediment and
debris from the bilge water.
29. Vertical ladder (figure 3, item 29). The vertical ladder provides access to the starboard day tank and the starboard
lifeboat station on the 02 level.