Custom Search
 
  
 
TM 55-1925-273-10-1
0028 00
Table 1. Major Functional Components of the ROWPU System (continued) (Refer to Figure 6)
Item No.
Nomenclature
Description
(Refer to
Figure 6)
15
ROWPU System 24 Vdc
The breaker and meter provide the operator with a means of
Control Panel
monitoring and securing 24 Vdc to the ROWPU locally. The battery
will still maintain a charge even if this switch is OFF. This switch must
be ON in order for the ROWPU to monitor the system and conduct
fresh water flushes.
16
ROWPU 24 Vdc Fuse Box
The fuse box provides 24 Vdc circuit protection in the event of a
battery bank or battery charger casualty.
17
ROWPU System 24 Vdc
The battery bank provides power to the controllers and to the
Battery Bank
fresh water flushing pump during layup periods. A properly
maintained and charged battery will provide adequate power to
maintain the weekly fresh water flushing cycle for up to 90 days
without recharging.
18
ROWPU System 24 Vdc
The battery charger/power supply provides 24 Vdc to recharge the
Battery Charger/Power
battery, and it provides 24 Vdc during normal ROWPU operation.
Supply
0028 00-9


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business