Custom Search
 
  
 
TM 55-1925-273-10-1
0043 00
Table 1. Engine Room, Miscellaneous Systems (refer to figure 1) (continued)
Key
Control/Indicator
Function
23
OB-17, OILY WASTE STOR.
This valve secures the flow of oily waste into the oily waste storage tank.
INLET Valve
24
OB-10, OILY WTR. SEP.
This valve secures the flow of oily water separator effluent overboard.
OVBD. DISCH Valve
25
BATTERY CHARGER
This battery charger charges the battery bank for the machinery dc control
MACHINERY DC CONTROL
panel (figure 1, item 21). Refer to figure 10 for details.
26
Battery Bank, MACHINERY
This battery bank is used to power the machinery's dc control system.
DC CONTROL
27
OB-16, OILY WASTE STOR.
This valve secures the suction line for the oily waste storage tank.
TK. SUCT. Valve
28
Oil Content Monitor
This unit monitors the oil content of the OWS effluent. Refer to figure 11
for details.
29
Oil Water Separator
This separates oil from the oily waste water prior to discharging the water
from the vessel. Refer to figure 10 for details.
30
Oily Waste Discharge Pump
This is used to pump the oily waste to an approved shore facility.
Refer to figure 13 for details.
31
Oily Waste System Discharge
This duplex strainer removes debris from the oily waste discharge pump's
Pump Inlet Strainer
inlet piping. Refer figure 13 for details.
32
FO-35, F.O. RTN TO DAY TK.
This cutoff valve controls the flow of fuel oil into the day tank.
STBD
33
FO-37, F.O. RTN RLF - SET AT
This gauge displays the fuel oil return relief pressure.
10 P.S.I.
34
Space Heater
This space heater provides heat for the engine room. Refer to figure 14
for details.
35
OB-3, OILY BILGE SUCT.
This valve controls oily bilge suction from the starboard shaft alley.
SHAFT ALLEY
36
OB-7, OILY DR. TK.
This valve secures the suction line from the oily drain tank.
SUCT Valve
37
Reduction Gear 1 Cooling
This motor controller controls the motor for the reduction gear 1 cooling
Pump Motor Controller
pump. Refer to figure 15 for details.
38
Reduction Gear 2 Cooling
This controls the motor for the reduction gear 2 cooling pump. Refer to
Pump Motor Controller
figure 15 for details.
39
OB-5, OILY BILGE SUCT.
This valve secures the oily bilge suction for the starboard side of the engine
ENG. RM. Valve
room.
40
OB-21, HOSE CONN. - OILY
This valve provides a connection and cutoff for the engine room aft oily
BILGE SUCT.
bilge.
41
Raw Water Strainer, Fire and
This strainer removes debris from the fire pump and general service pumps'
General Service Pump Suction
suction line.
42
Refrigeration Valve Manifold
This manifold permits control of the refrigeration and air conditioning
systems. Refer to figure 16 for details.
0043 00-3


 