Custom Search
 
  
 
TM 55-1925-273-10-1
0044 00
MACHINERY REMOTE CONTROL STATION
2
1
4
5 6 7
10
8
9
3
11
25
STOP
STOP
START
START
NO. 1
NO. 2
24
MAIN ENGINE
MAIN ENGINE
12
23
NO. 1
13
FIRE PUMP
22
STOP
STOP
START
START
14
START
SSDG NO. 1
SSDG NO. 2
21
STOP
15
STOP
STOP
START
START
NO. 2
FIRE PUMP
PUMP DRIVE
NO. 1 & NO. 2
ENGINE
HYD PUMP
17
18
20
19
16
Figure 8. Machinery Remote Control Station
Table 8. Machinery Remote Control Station (refer to figure 8)
Key
Control/Indicator
Function
1
NO. 1 MN ENG START
This pushbutton is used to start the starboard main engine.
Pushbutton
2
NO. 1 MN ENG STOP
This pushbutton is used to stop the starboard main engine.
Pushbutton
3
Indicator
This indicator illuminates to indicate that the starboard main engine is
running.
4
NO. 2 MN ENG START
This pushbutton is used to start the port main engine.
Pushbutton
5
NO. 2 MN ENG STOP
This pushbutton is used to stop the port main engine.
Pushbutton
6
Indicator
This indicator illuminates to indicate that the port main engine is running.
7
SSDG NO. 2 START Pushbutton
This pushbutton is used to start the SSDG 2 engine.
8
SSDG NO. 2 STOP Pushbutton
This pushbutton is used to stop the SSDG 2 engine.
9
Indicator
This indicator illuminates to indicate that the SSDG 2 engine is running.
10
NO. 1 FIRE PUMP START
This pushbutton is used to start fire and general service pump 1.
Pushbutton
0044 00-12


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business