Custom Search
 
  
 
TM 55-1925-273-10-1
0067 00
EDG OPERATION
Manual Run:
1.
Start EDG (see operating instruction)
2.
Open Main Bus Tie Breaker (Note: For push-button operation of motorized Main Bus Tie Breaker, mode
switch must be in 'Hand' or 'Auto' and door on breaker closed.)
3.
Close EDG breaker.
STAND BY (Normal at-sea condition):
1.
Place MODE switch to "AUTO".
2.
Place EDG engine control switch to auto start (see operating instructions).
3.
Ensure that EDG engine is set up for STAND BY operation (see operating instructions).
4.
Upon loss of power from main switchboard:
EDG will start, the main bus tie circuit breaker will open and the EDG breaker will close automatically.
FEEDBACK MODE
With EDG running and breaker closed:
1.
Ensure that no power is fed to the main switchboard, (i.e., SSDG No.1, SSDG No. 2 and shore power
breakers are open).
2.
Insert key and turn to feedback position.
3.
Close main bus tie breaker and either 1S/E or 2S/E breaker on main switchboard.
Placard 13. Switchboard (Sheet 2 of 3)
0067 00-19


 