Custom Search
 
  
 
TM 55-1925-273-10-1
0069 00
MACHINERY MONITORING SYS
CPU MULTIREMOTE
1
OFF
ON
Figure 10. Machinery Monitoring System CPU Multi-Remote Panel
2.
At Ship Service Diesel Generator (SSDG) 1, align the fuel oil service system and the fresh water cooling system by
opening the following valves:
a.
FO-21, F.O. SPLY TO S.S.D.G. No. 1 (figure 11, item 1)
b.
Fuel oil filter inlet valves (figure 11, item 2)
c.
Fuel oil filter outlet valves (figure 11, item 3)
d.
Fwc-9, F.W. F.R KEEL CLR TO S.S.D.G. No. 1 (figure 11, item 4)
e.
Fwc-11, F.W. FR. S.S.D.G. No. 1 TO KEEL CLR. (figure 11, item 5)
f.
FO-15, F.O. SERV. SUCT. STBD (figure 11, item 6)
g.
FO-35, F.O. RTN TO DAY TK. STBD (figure 11, item 7)
3.
Start the generator engine.
NOTE
Perform step a. only if the engine has not been run for several weeks or if all of the fuel was used
during a previous operation.
a.
Flood the SSDG 1 engine fuel system by using the hand-operated fuel oil priming pump (figure 12, item 1) until a
slight pressure is indicated on the engine fuel pressure gauge (figure 12, item 2).
0069 00-6


 


Privacy Statement - Copyright Information. - Contact Us