Custom Search
 
  
 
TM 55-1925-273-10-1
0080 00
4.
At the ROWPU 1 system controller (figure 9, item 14), perform the following:
a.
Press the STOP pushbutton (figure 25, item 1) and verify that the SYSTEM OFF indicator (figure 25, item 2) is
illuminated.
b.
Press the START pushbutton (figure 25, item 3) and verify the following:
(1)
BOOSTER PUMP indicator (figure 25, item 4) illuminates.
(2)
SYSTEM ON indicator (figure 25, item 5) is illuminated.
5.
Verify the following conditions at the ROWPU 1 flow control panel (figure 21, item 9):
a.
The BRINE flow meter (figure 21, item 12) displays a minimum flow reading of 4 gallons (15.1 liters) per minute
with no bubbles present.
b.
The BRINE DISCHARGE PRESSURE gauge (figure 21, item 15) indicates less than 15 PSI (1 bar).
c.
The PRODUCT WATER OUTPUT PRESSURE gauge (figure 21, item 16) indicates approximately 0 PSI (0.0 bar).
d.
The SYSTEM OPERATION PRESSURE gauge (figure 21, item 13) indicates less than 50 PSI (3.4 bar).
e.
The PRODUCT WATER flow meter (figure 21, item 17) indicates less than 1 gallon (3.8 liters) per hour.
6
2
8
4
5
3
1
7
Figure 25. System Controller
0080 00-22


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business