Custom Search
 
  
 
TM 55-1925-273-10-1
0086 00
b.
If the crane exceeds 100% of its rated capacity for a given condition, the overload alarm will activate. In this mode,
the following indications are given:
1)
The overload screen (figure 12) will appear, and the alarm beeper will beep rapidly.
2)
After approximately 10 seconds, the overload screen (figure 12) will be replaced by the primary operating
screen (figure 10). As long as the overload condition is present, the bar graph (figure 10, item 4) will be
replaced by a flashing OVERLOAD text message and the alarm beeper will beep rapidly.
c.
When the crane's boom angle falls below the minimum value for the load chart (0.0), the minimum boom angle
alarm will activate. In this mode, the following indications are given:
1)
The minimum boom angle alarm screen (figure 13) will appear on the LCD display (figure 2, item 1).
2)
The alarm beeper will beep rapidly.
3)
After approximately 10 seconds, the LCD display (figure 2, item 1) will alternate between the minimum
boom angle alarm screen (figure 13) and the primary operating display screen (figure 10).
d.
When the crane's boom angle exceeds the maximum value for the load chart (80.0), the maximum boom angle
alarm will activate. In this mode, the following indications are given:
1)
The maximum boom angle alarm screen (figure 14) will appear on the LCD display (figure 2, item 1).
90% Maximum Capacity LOAD MAIN
Reduce Load Moment
Figure 11. 90% Overload Screen
Maximum Capacity LOAD MAIN
Reduce Load Moment
Figure 12. Overload Screen
ANGLE MAIN
Below Load Chart
Please Correct
Figure 13. Minimum Boom Angle Alarm Screen
ANGLE MAIN
Above Load Chart
Please Correct
Figure 14. Maximum Boom Angle Screen
0086 00-5


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business