Custom Search
 
  
 
TM 55-1925-273-10-1
0091 00
REFRIGERATOR
The following procedures describe how to operate and shut down the refrigerator.
1.
At 120V distribution panel No. 1, set the REFRIGERATOR. circuit breaker (figure 4, item 7) to ON.
NOTE
All controls are factory set for proper operation. If the thermometer reads below 37 F (3 C) or
above 43 F (6 C) refer to unit maintenance. It is important that the refrigerator not be loaded
with perishables until the inside temperature has reached operating level. This will take approxi-
mately 3 hours.
2.
Allow space for the air to circulate within the refrigerator for maximum efficiency.
3.
To shut down the refrigerator, set the REFRIGERATOR. circuit breaker (figure 4, item 7) in 120V distribution
panel No. 1 to OFF.
4.
If the freezer is not to be used for an extended period, block the door OPEN.
FREEZER
The following procedures describe how to operate and shut down the freezer.
1.
At 120V distribution panel No. 1, set the FREEZER. circuit breaker (figure 4, item 8) to ON.
NOTE
All controls are factory set for proper operation. If the thermometer reads below -5 F (-21 C) or
above 0 F (-18 C) refer to unit maintenance. It is important that the freezer not be loaded with
perishables until the inside temperature has reached operating level. This will take approxi-
mately 3 hours.
2.
Allow space for the air to circulate within the freezer for maximum efficiency.
3.
To shut down the freezer, set the FREEZER. circuit breaker (figure 4, item 8) in 120V distribution panel No. 1 to OFF.
4.
If the freezer is not to be used for an extended period, block the door OPEN.
END OF WORK PACKAGE
0091 00-30


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business