Custom Search
 
  
 
TM 55-1925-273-10-2
0118 00
2
1
3
5
POWER
AVAILABLE
START
4
STOP
6
MANUAL
AUTO
1
Figure 5. Fire and General Service Pump No. 1
Figure 4. Emergency Switchboard
Motor Controller
PUMPING THE AFT ENGINE ROOM BILGE USING FIRE AND GENERAL SERVICE PUMP 1
1.
CLOSE valve FM-3, S.W. TO BILGE/BLST. PMPS. (figure 2, item 5).
2.
OPEN valve FM-4, EMER BILGE SUCT (figure 2, item 6).
3.
Start the pump by completing the following at the fire and general pump No. 1 motor controller:
a.
Press START (figure 5, item 4).
b.
Verify that the MOTOR RUN indicator (figure 5, item 5) illuminates.
4.
When pumping is complete:
a.
Press STOP (figure 5, item 6) at the fire and general service pump No. 1 motor controller.
b.
Verify that the MOTOR RUN indicator (figure 5, item 5) goes out.
c.
CLOSE valve FM-4, EMER BILGE SUCT (figure 2, item 6).
d.
Perform the Secure From Emergency Bilge Pumping procedure in this work package.
PUMPING BILGES OTHER THAN THE AFT ENGINE ROOM BILGE USING FIRE AND GENERAL SERVICE
PUMP 1
1.
OPEN valve FM-3, S.W. TO BILGE/BLST. PMPS. (figure 2, item 5)
2.
CLOSE valve FM-4, EMER BILGE SUCT (figure 2, item 6).
0118 00-5


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business