Custom Search
 
  
 
TM 55-1925-273-10-2
0131 00
Table 19. Pad Eyes Label Plates
(1)
(2)
(3)
(4)
(5)
INSCRIPTION
SECURE TO
MATL
ATT
TYPE
(table 23)
(table 24)
(table 25)
WORKING LOAD 7000 LB
MN DK UNDER SIDE, FR 55.5 ON
AL
T
F
TEST LOAD 14000 LB
C.L. GIRDER AJD TO PAD
WORKING LOAD 3000 LB
MN DK UNDER SIDE, FR 53 ON
AL
T
F
TEST LOAD 6000 LB
C.L. GIRDER AJD TO PAD
WORKING LOAD 3000 LB
MN DK UNDER SIDE, FR 50 ON
AL
T
F
TEST LOAD 6000 LB
C.L. GIRDER AJD TO PAD
WORKING LOAD 3000 LB
MN DK UNDER SIDE, FR 52,
AL
T
F
TEST LOAD 6000 LB
66" OFF C.L. STBD, ON
INSULATION ADJACENT TO
PADEYE
WORKING LOAD 3000 LB
MN DK UNDER SIDE, FR 49,
AL
T
F
TEST LOAD 6000 LB
66" OFF C.L. STBD, ON
INSULATION ADJACENT TO
PADEYE
WORKING LOAD 3000 LB
MN DK UNDER SIDE, FR 45,
AL
T
F
TEST LOAD 6000 LB
6'-2" OFF C.L. STBD, ON
INSULATION ADJACENT TO
PADEYE
WORKING LOAD 3000 LB
MN DK UNDER SIDE, FR 42,
AL
T
F
TEST LOAD 6000 LB
6'-2" OFF C.L. STBD, ON
INSULATION ADJACENT TO
PADEYE
WORKING LOAD 3000 LB
MN DK UNDER SIDE, FR 39,
AL
T
F
TEST LOAD 6000 LB
6'-2" OFF C.L. STBD, ON
INSULATION ADJACENT TO
PADEYE
WORKING LOAD 7000 LB
MN DK UNDER SIDE, FR 41.5,
AL
T
F
TEST LOAD 14000 LB
9'-10" OFF C.L. P/S, ON
INSULATION ADJACENT TO
PADEYE
WORKING LOAD 7000 LB
MN DK UNDER SIDE, FR 37.5,
AL
T
F
TEST LOAD 14000 LB
9'-10" OFF C.L. P/S, ON
INSULATION ADJACENT TO
PADEYE
WORKING LOAD 7000 LB
MN DK UNDER SIDE, FR 37,
AL
T
F
TEST LOAD 14000 LB
6'-6" OFF C.L. P/S, ON
INSULATION ADJACENT TO
PADEYE
0131 00-88


 