TM 55-1925-273-10-2
0137 00
Table 1. Preventive Maintenance Checks and Services Including Lubrication (continued)
ITEM INTERVAL MAN-
ITEM TO BE
PROCEDURE
EQUIPMENT
NO.
HOUR
CHECKED OR
NOT READY/
SERVICED
AVAILABLE IF:
19
Before
1.0
Pressure Reducing
Inspect all pressure reducing valves for
Pressure reducing
Valves
proper operation. Report discrepancies/
valve inoperative.
damage to engineer on watch and unit
maintenance.
Pressure Reducing Valve
20
Before
1.0
Sanitary Spaces
Visually inspect all faucets on lavatories
Class III leaks from
and showers for leaks. Inspect all water
the sewage system.
closets for leaks and stoppage.
Inspect the shower and lavatory drains
to ensure that they are unstopped. If
Class III leakage is observed, or if drains
or commodes are stopped, refer to
supervisor and to unit maintenance.
Shower
Faucets
Lavatory
Water Closet
Lavatory Drain
0137 00-10


 