Table 1. Preventive Maintenance Checks and Services Chart (continued)
ITEM INTERVAL MAN-
ITEM TO BE
PROCEDURE
EQUIPMENT
NO.
HOUR
CHECKED OR
NOT READY/
SERVICED
AVAILABLE IF:
MAIN
PROPULSION
ENGINES
106
Monthly
0.5
Water Jacket Heater
Check for proper operation by placing
your hand near, but not on the block.
Warmth should be felt.
107
Monthly
0.5
Soak Back Pump
Verify that the soak back pump operates
Soak back system
for 25 minutes when the start button is
does not operate.
pushed.
Handhole
Air Box
Covers
Cylinder Test
Drain
Valve
Dipstick
Air Line
Lubricator
108
Monthly
0.5
PRELUBE PUMP
Inspect pump for leaks, loose connections, Pump is defective.
and damage.
Electric
Coupling
Motor
Prelube Pump
0138 00-42


 