Custom Search
 
  
 
NOTES:
1.
FOR  OPERATION  OF  EQUIPMENT  IN
9.
STARTING SYSTEM FILTER. Drain reservoir
PROTRACTED COLD TEMPERATURES BELOW -10
and service filter as specified in TM 55-1905-217-12.
F.  Remove lubricants prescribed in the key for
temperatures above -10 . Lubricate with lubricants
F
10.
STEERING CYLINDERS.  Remove pin and
specified in the key for temperatures below -10 .
F
lubricate pin sparingly and replace pin.
2.
WINCH.
Remove inspection plate and
11.
STEERING TIE BAR.
Remove pin and
remove oil level plug to check oil level.  Add
lubricate pin sparingly and replace pin.
lubricant as required at fill to bring up to level plug.
Replace oil level plug and inspection cover.
12.
RAMP HOIST CABLE.  Clean and lubricate
with CW every 250 hours.  CW - lubricating oil,
3.
BOW SHEAVE.
Remove cover plate to
exposed gear.
lubricate; replace cover plate.
13.
RAMP LOCKING CYLINDER Grease every 50
4.
RAMP SHEAVES.  Lubricate through drain
hours.
holes on underside of ramp.  One fitting each
sheave.
You  can  improve  this  publication  by  calling
attention  to  errors  and  by  recommending
5.
BILGE PUMPS. Turn down grease cup one
improvements and by stating your reasons for the
full turn to lubricate.
recommendations.
Your
letter
or
DA2028,
Recommended Changes to Publications and Forms
6.
STEERING  SYSTEM  AND  RAMP  HOIST
should be mailed directly to U.S.  Army Troop
SYSTEM FILTERS. Steering System filters must be
Support and Aviation Material Readiness Command
changed at 500 hour interval.
Attn:  DRSTS-MTPS, 4300 Goodfellow Blvd., St.
Louis, Mo. 63120.
Ramp Hoist System filters must be changed at 250
hour interval.
Copy of this Lubrication Order will remain with the
equipment at all times; instructions contained
7.
STEERING SYSTEM STRAINER. Drain fluid
herein are mandatory.
from tank.  Remove tank top cover and remove
strainer.
Clean strainer in solvent and reinstall. Fill steering
system with fluid at expansion tank in pilot house.
By Order of the Secretary of the Army
8.
RAMP  HOIST  SYSTEM  STRAINER  AND
RESERVOIR. Clean element when indicator reads in
E. C. MEYER
red zone.  Remove and service filter and refill
General United States Army
Chief of Staff
reservoir as specified in TM 55-1905-217-12.
Official
J. C. PENNINGTON
Major General, United States Army
The Adjutant General


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business