Custom Search
 
  
 
LO 55-1905-223-12
INTERVAL LUBRICANT
LUBRICANT INTERVAL
OC
Crankcase OIl
OE/HDO
250
Fill Cap
OE/HDO
Crankcase Oil
(C)
Level Gauge
(See Note 17)
Engine Oil
OE/HDO
OC
D
(C)
Bypass Filter
250
(Remove, Clean,
Replace)
OE/HDO
Engine Oil
(See Note 16)
Filter, AOAP
(C)
OC
Analysis
S
250
(Remove, Clean,
Bearing Grease
GAA
Replace)
Fitting (3 places)
(See Note 16)
(See Note 20)
(C)
(C)
OC
250
S
Crankcase Drain  OE/HDO
GAA
Bearing Grease
(Drain, Fill)
Fittings
(See Notes 18, 19)
(See Note 20)
(C)
NT 885-M BOW THRUSTER ENGINE
(C)
TOTAL TASK-HOURS*
TOTAL TASK-HOURS*
INTERVAL
TASK-HOURS
INTERVAL
TASK-HOURS
OC or 250
1.0
D
0.1
0.5
OC or 250
1.0
S
0.5
S
-KEY-
EXPECTED TEMPERATURES
CAPACITY
INTERVALS
ALL TEMPERATURES
OE/HDO
Lubricating oil,
D-Daily
(MIL-PRF-2104)
internal combustion
11 gallons
15W/40
S-Semiannually
engine, tactical service
OC-On Condition
GAA
Grease, automotive
As Required
(MIL-PRF-10924) and artillery
Notes:
16. Install filters, fill crankcase. Operate at idle and inspect for leaks. Shut off engine, and allow 5 minutes for oil to
drain to crankcase. Check oil level with dipstick.
17. Check crankcase level with engine shutdown.
18. A sample of oil shall be sent to an AOAP Laboratory for analysis at an interval of 100 hours or 90 days for Active Army
and 50 hours or 180 days for USAR/NG. Refer to TB 43-0211 for sampling requirements.
19. When AOAP Laboratory support is not available, drain and refill crankcase at 250 hours or 6 months.
20. Clean grease fitting. Apply 2 or 3 strokes of grease from a hand held lubrication gun. Wipe off excess.
Card 5 of 41


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business