(j)
Batteries - New, in dry state will be secured in their respective racks. Lugs and terminals will be cleaned and
coated with P-11 and left unconnected. Electrolyte is stored in the storeroom on board the ROWPU.
(k)
Helm Pump Hydraulics- Fill reservoir to operating level with Seastar hydro fluid or Texico Aircraft HO-15.
(l)
Cabin - Static pack with 480 units (30-16 unit bags) of desiccant. Seal fwd. door and aft. booby hatches
with pressure sensitive tape, glue and strippable coating. Install a humidity indicator so as to be visible thru
one of the windows.
(m)
Engine Compartment - Static pack with 480 units of desiccant (30-16 unit bags). Seal hatch with pressure
sensitive tape, glue and strippable coating.
NOTE
Store the desiccant in the basket provided and suspend the basket to
allow air circulation around the desiccant.