Custom Search
 
  
 
TB 600-1
SECTION XI
PART IV
STOPPING A 5KW GENERATOR SET AND PERFORM AFTER OPERATION CHECKS
PERFORMANCE MEASURES
(Scored in Sequence)
PASS
FAIL
____
____
*1.
Stopping Instructions. Uses stopping instructions in TM 5-6115-332-14.
*2.
Circuit Breaker. Place circuit breaker in the OFF position.
____
____
*3.
Cool Down. Allows engine to cool down at rated speed three to fifteen minutes.
____
____
*4.
Start-Stop Switch. Place start-stop switch in the stop position.
____
____
5.
Ear Protection. Remove ear protection.
____
____
*6.
Operator/Crew Preventive Maintenance Checks and Service. Uses TM 5-6115-
332-14 and TM 5-2805258-14 to perform after operation checks.
____
____
*7.
Generator Set. Visually inspect the generator set for fuel and oil leaks.
____
____
*8.
Fuel Tank. Refuel tank after completion of daily operation.
____
____
*9.
Refueling. Provide metal to metal contact between fuel container and fuel tank.
____
____
*10.
Engine. Inspect the engine for loose or missing wiring, parts, and any oil or fuel
leaks.
____
____
*11.
Oil Level Gage. Check oil level. Add if necessary.
____
____
*12.
Fuel Filter. Inspect fuel filter for dirt, water, or sediment.
____
____
*13.
Oil Filter. Inspect for oil leaks.
____
____
14.
Fuel Selector Valve. Place fuel selector valve in the OFF position.
____
____
15.
Electrolyte. Use extreme care when handling electrolyte (batteries)
____
____