Custom Search
 
  
 
TB 600-1
PASS
FAIL
*10.
Master Switch. Do not hold switch in start position longer than 15 seconds. Allow
a starter cooling period of one minute before attempting to restart.
____
____
*11.
Master Switch. Will return to prime and run position when released. If running
from auxiliary fuel source, move master switch to prime and run auxiliary fuel
position.
____
____
*12.
Check Oil Pressure on Engine Mounted Gage. Oil pressure should be at least 20
psi minimum.
____
____
*13.
Check Frequency on Frequency Meter.
On control panel adjust governor, if
necessary, using speed control.
____
____
*14.
Frequency Meter. Frequency meter should read 61.5 with no load. If not, pulling
speed control knob out will increase frequency.
____
____
*15.
Engine Warm up. Allows engine three to five minutes to warm up.
____
____
*16.
Voltmeter 120/240 120/208. Rotate voltage selector to monitor the voltage of
each phase combination.
____
____
*17.
Battery Charging Ammeter.
Should read zero or any reading on plus side of
scale.
____
____
*18.
Fuel Filters. Inspect for fuel leaks.
____
____
*19.
Oil Filter. Inspect for oil leaks.
____
____
*20.
Engine. Inspect engine for loose or missing wiring, parts, and any oil or fuel
leaks.
____
____
*21.
Engine and Accessories. The engine and engine accessories that are hot should
not be touched with the bare hands during operation or before they have cooled
____
____
sufficiently.
Change 3 H-47


 