0036 00
TM 11-5895-1847-12&P
TALKER DEVICE
TALKER ID
INDICATION
DECCA
DE
DC
INTEGRATED
II
DR
INSTRUMENTS
OMEGA
OM
OMEGA
Nav. print ready.
End of print NMEA data
Manual print NMEA data
2C036-15
45. When navigation data is fed to the receiver it may be used as a data logger, or a peripheral printer for navigation
equipment.
NOTE
To feed navigation data, a connector assembly (optional supply) is required.
When no navigation equipment is connected, the following descriptions can
be disregarded.
46. To select navigation data to be printed, select "C" on the main menu and set NMEA (or CIF) to ON by entering
lower case character "e", then press ENT key. The receiver prints out the following.
*
printing head
A B C D E F G H I ESC
current setting
Set NMEA item
Capital = Selected Small = Deselected
A: Time
B: Heading
C: Position
D: Speed
E: Bearing
F: Wind direction, velocity
G: Water temperature
H: Depth
I: Current direction, velocity
ESC: ESCAPE
2C036-16
NOTE
"CIF" may be printed instead of "NMEA" depending on internal setting.
47. Enter upper or lower case characters to select or deselect navigation data, respectively. Press the ENT key to
register selections.
0036 00 16


 