TM 11-5895-1847-12&P
0142 00
INSTALL GMDSS POWER SUPPLY
1.
Position and align GMDSS DC converter (4) to mounting structure stand-offs (12).
2.
Install four bolts (9), lock washers (10) and flat washers (11) through GMDSS DC converter (4) and into
mounting structure stand-offs (12). Tighten bolts (9).
3.
On DC converter (4), attach INPUT 13.6VDC positive wire and terminal (8) on negative post (-) and tighten
nut (16).
4.
On DC converter (4), attach INPUT 13.6VDC negative wire (7) on positive post (+) and tighten nut (15).
5.
On DC converter (4), attach INPUT 20-50VDC negative wire (6) on negative post (-) and tighten nut (14).
6.
On DC converter (4), attach INPUT 20-50VDC positive wire (5) on positive post (+) and tighten nut (13).
7.
In radio room fuse box (1) install fuses.
8.
Position fuse box cover (3) and secure using 1/4 turn captive screws (2).
END OF WORK PACKAGE
0142 00 3/4 blank