Custom Search
 
  
 
0144 00
TM 11-5895-1847-12&P
a.
Loosen two screws (6) on clamp (8).
b.
Pull GMDSS POWER cable (2) from junction box (1).
2.
Remove J5 cable (3) from junction box (1).
a.
Loosen two screws (7) on clamp (9).
b.
Pull J5 cable (3) from junction box (1).
3.
Remove PLGRSB-PWR/DC POWER cable (4) from junction box (1).
a.
Loosen two screws (10) on clamp (11).
b.
Pull PLGRSB-PWR/DC POWER cable (4) from junction box (1).
4.
Remove four bolts (5), eight washers (12) and four nuts (13). Remove junction box (1).
INSTALL JUNCTION BOX
1.
Align junction box (1) with mounting holes and install four bolts (5), eight washers (12) and four nuts (13).
Tighten bolts (5) and nuts (13).
12
13
5
1
8
6
2
3
9
7
10
11
4
2C139-1
2.
Install PLGRSB-PWR/DC POWER cable (4) in junction box (1).
a.
Push PLGRSB-PWR/DC POWER cable (4) into junction box (1).
b.
Tighten two screws (10) on clamp (11) to secure cable.
0144 00 2


 